Hioki
is proud to release the World’s
First ever Flip Cover Current
Clamp On meters. The True
RMS model 3293 provides exceptional
dynamic range for measuring leak to load
from 30mA to 1000A with 10uA of resolution.
The True RMS model 3291 offers
multiple range selection to measure load
up to 1000A. In the past, many a user has
suffered the frustration experienced when
clamping around a conductor and the display
is obstructed. Many have been unable
to see the display in the darkness of
the enclosure or many have found it
nearly impossible to clamp around a conductor
because of narrow spacing. This new flip clamp solves all of those inconveniences
with the simple flip of the display
panel for easy visibility. The brilliant
backlight ensures a bright and clear display
and the thin advanced sensor clamps
easily even in the most narrow of spaces.
More advanced features include simply
opening the jaws of the clamp to activate
the instrument and begin measurement; a
bar graph monitor
shows fluctuations
at the measurement
point and
measurement
results can be
read at any angle.
Standard
functions of
both units include
Auto Range
Switching, Display
Hold, Maximum Value
Hold, REVERSIBLE LCD
DISPLAY, Backlight, Auto
Power On, Auto Power Off, and
Battery Level Indication. Their super
thin compact design allows the double
lever jaw mechanism to get into even the
narrowest of spaces. Their advanced sensor
makes it safe to clamp on bare conductors.
Simply open the jaw to turn the
power on. Flip the cover to rotate the display
and view measurements from any angle.
Included is a bright backlight and an
advanced filter to cut off noise components
from harmonic and other sources.
Rounding out the benefits of these revolutionary clamps is their ability to measure
for maximum value simultaneously and
hold max value on the bar graph. This
new clamp design emphasizes ease of use.
Non-Metallic
Phase Detector Series
Hioki announces its new Phase Detector
models 3129 and 3129-10 series. This new series offers the only CATIII 1000V
CATIV 600V Non-Metallic Detectors on
the market! In the past, the conventional
phase rotation detector required the technician
to clamp onto exposed metallic
parts of the conductor with metallic clips
thus introducing the potential danger of
electrical shock caused by the contact between
two metal points. The 3129 series
Non-Metallic clips ensure absolute safety
by utilizing fully enclosed ABS molded
clips with no metal exposure. Based on
the electrostatic induction theory, the 3129
series Phase Detectors can safely and accurately
detect rotation in three phase circuits.
Correct rotation is indicated by a crystal clear beeping tune while bright red
LEDs show the rotation direction. The
3129 series detectors can accommodate
insulated wire diameters from 2.4 to
40mm and voltage ranges up to 1000V
AC depending on the model selected. Advanced
features include bright red LEDs
to detect phase orientation even in poorly
lit locations; a buzzer provides audible
recognition of phase detection; a live wire
check function to easily detect hot wires; a
compact & lightweight design; auto
power off function; and a low battery indicator.
The 3129 series includes the best
features of product safety for quick and
easy testing.























