World’s First Flip Clamp Series

Hioki is proud to release the World’s First ever Flip Cover Current Clamp On meters. The True RMS model 3293 provides exceptional dynamic range for measuring leak to load from 30mA to 1000A with 10uA of resolution. The True RMS model 3291 offers multiple range selection to measure load up to 1000A. In the past, many a user has suffered the frustration experienced when clamping around a conductor and the display is obstructed. Many have been unable to see the display in the darkness of the enclosure or many have found it nearly impossible to clamp around a conductor because of narrow spacing. This new flip clamp solves all of those inconveniences with the simple flip of the display panel for easy visibility. The brilliant backlight ensures a bright and clear display and the thin advanced sensor clamps easily even in the most narrow of spaces. More advanced features include simply opening the jaws of the clamp to activate the instrument and begin measurement; a bar graph monitor shows fluctuations at the measurement point and measurement results can be read at any angle. Standard functions of both units include Auto Range Switching, Display Hold, Maximum Value Hold, REVERSIBLE LCD DISPLAY, Backlight, Auto Power On, Auto Power Off, and Battery Level Indication. Their super thin compact design allows the double lever jaw mechanism to get into even the narrowest of spaces. Their advanced sensor makes it safe to clamp on bare conductors. Simply open the jaw to turn the power on. Flip the cover to rotate the display and view measurements from any angle. Included is a bright backlight and an advanced filter to cut off noise components from harmonic and other sources. Rounding out the benefits of these revolutionary clamps is their ability to measure for maximum value simultaneously and hold max value on the bar graph. This new clamp design emphasizes ease of use.

Non-Metallic Phase Detector Series
Hioki announces its new Phase Detector models 3129 and 3129-10 series. This new series offers the only CATIII 1000V CATIV 600V Non-Metallic Detectors on the market! In the past, the conventional phase rotation detector required the technician to clamp onto exposed metallic parts of the conductor with metallic clips thus introducing the potential danger of electrical shock caused by the contact between two metal points. The 3129 series Non-Metallic clips ensure absolute safety by utilizing fully enclosed ABS molded clips with no metal exposure. Based on the electrostatic induction theory, the 3129 series Phase Detectors can safely and accurately detect rotation in three phase circuits. Correct rotation is indicated by a crystal clear beeping tune while bright red LEDs show the rotation direction. The 3129 series detectors can accommodate insulated wire diameters from 2.4 to 40mm and voltage ranges up to 1000V AC depending on the model selected. Advanced features include bright red LEDs to detect phase orientation even in poorly lit locations; a buzzer provides audible recognition of phase detection; a live wire check function to easily detect hot wires; a compact & lightweight design; auto power off function; and a low battery indicator. The 3129 series includes the best features of product safety for quick and easy testing.

 

 

 



About Us | Privacy Policy | Contact Us | ©2004 ABD Communications

Click here to view our BPA Statement